Link-systems OmniLink - Feed Interface Instrukcja Użytkownika Strona 1

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Urządzenia pomiarowe Link-systems OmniLink - Feed Interface. LINK Systems OmniLink - Feed Interface User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 40
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
OmniLink 5000
System 5000
Press Control
FEED INTERFACE
OPERATING MANUAL
LINK ELECTRIC & SAFETY CONTROL COMPANY
444 McNALLY DRIVE, NASHVILLE TN 37211
PH (615)-833-4168 FAX (615)-834-1984
Przeglądanie stron 0
1 2 3 4 5 6 ... 39 40

Podsumowanie treści

Strona 1 - OmniLink 5000

OmniLink 5000System 5000Press ControlFEED INTERFACEOPERATING MANUALLINK ELECTRIC & SAFETY CONTROL COMPANY444 McNALLY DRIVE, NASHVILLE TN 3721

Strona 2

OmniLink 5000 Feed Manual December 13, 19992.4 Manual Rev 2.32.5 Coe ServoMaster InterfaceThe connection to a Coe ServoMaster Feed usestwo cables - a

Strona 3 - Table of Contents

OmniLink 5000 Feed Manual December 13, 19992.5 Manual Rev 2.32.6 CWP ServoDial II InterfaceThe connection to a CWP ServoDial II feed is asfollows:Tabl

Strona 4

OmniLink 5000 Feed Manual December 13, 19992.6 Manual Rev 2.32.8 CWP Servomatic InterfaceThe connection to a CWP Servomatic Feed is alittle more invo

Strona 5

OmniLink 5000 Feed Manual December 13, 19992.7 Manual Rev 2.32.9 CWP ServoMax II InterfaceThe connection to a CWP ServoMax II Feed(IQ2000/IQ5000 based

Strona 6

OmniLink 5000 Feed Manual December 13, 19992.8 Manual Rev 2.32.11 Dallas Feed Interface (EXOR Control)The connection to a Dallas feed with EXORcontro

Strona 7

OmniLink 5000 Feed Manual December 13, 19992.9 Manual Rev 2.32.13 Indramat CLM InterfaceConnections to the Indramat CLM are asfollows:Table 2.12Indram

Strona 8 - Link PN 100812

OmniLink 5000 Feed Manual December 13, 19992.10 Manual Rev 2.32.15 Indramat SOT InterfaceThe Indramat SOT (serial operator terminal) issometimes used

Strona 9 - Link PN 106739

OmniLink 5000 Feed Manual December 13, 19992.11 Manual Rev 2.32.16 Indramat CLM Version 1.2 InterfaceThis is an older version of Indramat firmware. Co

Strona 10 - Manual Rev 2.3

OmniLink 5000 Feed Manual December 13, 19992.12 Manual Rev 2.3g) Select “Enable Relay Mode”.2.18 PA Bullet/Edge/Advantage InterfaceThe connection to a

Strona 11

OmniLink 5000 Feed Manual December 13, 19992.13 Manual Rev 2.32.19 Rapid-Air InterfaceThe Rapid-Air interface is somewhat differentfrom most of the fe

Strona 13

OmniLink 5000 Feed Manual December 13, 19992.14 Manual Rev 2.32.19.2 Rapid-Air Connections with NewCommunications boardThe connection to a Rapid-Air F

Strona 14

OmniLink 5000 Feed Manual December 13, 19992.15 Manual Rev 2.32.20 Unico InterfaceThe connection to a Unico Feed is as follows:Table 2.21Unico Connect

Strona 15

OmniLink 5000 Feed Manual December 13, 19992.16 Manual Rev 2.32.22 Dynamic Feeds InterfaceThe Dynamic Feeds interface is somewhatdifferent from most o

Strona 16 - Link PN 106738

OmniLink 5000 Feed Manual December 13, 19993.1 Manual Rev 2.33. CONFIGURATIONThere are two different communication boardsthat have been used with the

Strona 17

OmniLink 5000 Feed Manual December 13, 19993.2 Manual Rev 2.3Figure 3.1: OmniLink 5000 MainConfiguration Screen Push the softkey for “OPERATORTERMINA

Strona 18 - Table 2.17

OmniLink 5000 Feed Manual December 13, 19993.3 Manual Rev 2.3Length Units - This is the unit in which to enterfeed length values. Using the arrow key

Strona 19

OmniLink 5000 Feed Manual December 13, 19993.4 Manual Rev 2.3the feed. Note that the units displayed to the rightof the value should be set as well.

Strona 20

OmniLink 5000 Feed Manual December 13, 19994.1 Manual Rev 2.34. OPERATIONThere are two different communication boardsthat have been used with the Omn

Strona 21

OmniLink 5000 Feed Manual December 13, 19994.2 Manual Rev 2.3Feed Length - The current feed length setting.This value is displayed in whatever units w

Strona 22 - Link PN 107833

OmniLink 5000 Feed Manual December 13, 19994.3 Manual Rev 2.3Figure 4.3: Storing Job with Feed OffIf the feed is off unintentionally, the operator may

Strona 23 - Board Configuration

Table of Contents1. INTRODUCTION ...1.11.1 Requirements ...

Strona 24

OmniLink 5000 Feed Manual December 13, 19995.1 Manual Rev 2.35. INTERFACING TO OTHER FEEDS OR DEVICESIn many cases a feed that is not currently suppo

Strona 25

OmniLink 5000 Feed Manual December 13, 19995.2 Manual Rev 2.3To Request Speed from the feed:5000 Sends:G2[CR]Feed Returns:G2[CR][LF]G2[S]=[S]XXXX.XXXX

Strona 26

OmniLink 5000 Feed Manual December 13, 19995.3 Manual Rev 2.3Examples of Length set:Operator enters 3.255 for feed length.5000 Sends:G1=003.255[CR]Fee

Strona 27

OmniLink 5000 Feed Manual December 13, 19995.4 Manual Rev 2.3G2=0100[CR][LF]G2[S]=[S]100.0000[CR][LF][CR][LF]PDM>

Strona 28

OmniLink 5000 Feed Manual December 13, 1999A.1 Manual Rev 2.3If the OIT software version is older thanversion 2.0, the OIT and motherboard softwareMUS

Strona 29

OmniLink 5000 Feed Manual December 13, 1999A.2 Manual Rev 2.3Figure A.1: System 1100 OIT Circuit BoardA.2.2 System 1100 Motherboard SoftwareUpgrade Pr

Strona 30

OmniLink 5000 Feed Manual December 13, 1999A.3 Manual Rev 2.3A.3 OmniLink 5000 Upgrade ProcedureMost OmniLink 5000 press controls shippedprior to July

Strona 31

OmniLink 5000 Feed Manual December 13, 1999A.4 Manual Rev 2.3Figure A.5: Operator Interface Terminal to NewCommunications Board ConnectionsA.3.2 OmniL

Strona 32

OmniLink 5000 Feed Manual December 13, 1999A.5 Manual Rev 2.3Note that communications cards can have upto two additional software chips as options. Re

Strona 33 - 5.4 Manual Rev 2.3

OmniLink 5000 Feed Manual December 13, 1999A.6 Manual Rev 2.3Figure A.9: OmniLink 5000 Die ProtectionModule Circuit Board Insert the new 5000-7 chip.

Strona 34

A.3.3 OmniLink OIT Communications Card Software Upgrade Procedure ... A.4A.3.4 OmniLink Logic Module Upgrade Procedure ...

Strona 35

OmniLink 5000 Feed Manual December 13, 1999A.7 Manual Rev 2.3Figure A.11: OmniLink Auto-Setup ModuleCircuit Board Insert the new 5000-10 chip. If a

Strona 36

OmniLink 5000 Feed Manual December 13, 19991.1 Manual Rev 2.31. INTRODUCTIONThe OmniLink 5000 Operator InterfaceTerminal (OIT) is equipped with a seri

Strona 37

OmniLink 5000 Feed Manual December 13, 19991.2 Manual Rev 2.3 The roll feed must be supported by theOmniLink 5000. Supported feeds at the timethis m

Strona 38

OmniLink 5000 Feed Manual December 13, 19992.1 Manual Rev 2.32. INSTALLATIONIn most cases, installation consists of simplyconnecting the appropriate c

Strona 39

OmniLink 5000 Feed Manual December 13, 19992.2 Manual Rev 2.3interface. This port is jumper selectable as a RS-232C port or a RS-485 port depending o

Strona 40

OmniLink 5000 Feed Manual December 13, 19992.3 Manual Rev 2.32.4 Coe BG2 InterfaceThe connection to a Coe BG2 Electronic Feed isas follows:Table 2.2Co

Komentarze do niniejszej Instrukcji

Brak uwag